Application: remove radioactive air and article from air during normal or accident conditions through carbon absorber.
Safety related ACU is designed, fabricated and verified according to ASME N509, N510, AG-1 standard.
Stainless steel work for carbon absorber
Type of absorber: type II,III,IV
1E class fire detective system
Qualified by IEEE 323 & 344 for seismic category I, and class 1E equipment;
Components: water and gas separator, electrical coil, low efficiency filter, high efficiency filter, carbon absorber, fan, motor, housing ,controlling cabinet and instrument.